<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-14 08-35-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 40 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
7 kHz 51 kHz 18777 0,1331
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,7 dBr -0,22 dBr 0,5 dBr 10,3
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 8:35, 14.09.2025
RT
"Vertikala - Jakou silu a vyznam maji gesta, ucinena v souvisl..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 51 kHz MIN: 7 kHz % above 77 kHz: 0,1331 Acquired: 2025/09/14 8:35:21 Total samples: 18777 Equivalent time: 0:15:38 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400 500
FM Scope MAX: 0,5 dBr MIN: -0,7 dBr AVE: -0,22 dBr % above 0,2 dBr: 10,3 Last value: 0,4 dBr (2025/09/14 8:35:20) 08:22 08:24 08:26 08:28 08:30 08:32 08:34 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality